Cadillac® EMAG Magnetic Flow Meter
The liquid meter of choice
The Cadillac® EMAG Magnetic Flow Meter has been acknowledged as the industry standard for accuracy and electronics innovation.
The Cadillac® EMAG magnetic flow meter is capable of measuring liquids of all types and consistency while providing an obstruction free flow path. While the EMAG has a traditional flow tube/coil design the EMAG shares the same electronics platform as the CMAG. This provides the EMAG with the same electronics capabilities that enhance the CMAG’s performance and thus enhances the EMAG capabilities in a similar fashion. The result is a reduced flow profiling or piping straight run requirement in comparison to meters with the same flow tube design eliminating more than half of the piping straight run in comparison.
The EMAG with its traditional flow tube design provides an economical alternative for those applications where some piping straight run or flow profiling is available. With a common electronics platform shared with the CMAG, the EMAG has all the electronics features and options available as standard and an industry standard accuracy of +/- 0.50% of rate or reading. In any conductive liquid application the Cadillac® magnetic flow meter is the number one technology choice due to Cadillac® ’s accuracy, linearity, reliability and rangeability.
The Hot/Chilled Energy Water Flow Meter of Choice
With improved flow profiling requirements over traditional flow meters the EMAG makes an excellent choice for both Hot and Chilled water energy applications, where some piping straight run is available.The EMAG electronics capability allows retrofit areas with some flow profiling, without affecting the measurement accuracy. In addition, the EMAG has a turn-down of 100:1, which is suited for many applications with modulating flow rates that remain above 1 ft/sec.
The Water and Wastewater Industry Standard
With its improved flow profiling or piping straight run requirement the EMAG makes an optimal choice for both water and wastewater applications. With line sizes common above 16 inches the EMAG allows new designs to eliminate long piping straight runs in order to get an accurate and reliable flow measurement. This helps reduce the footprint of a building or other areas where the flow meters would be mounted. With increased wetted material selections most Water, including potable (NSF/ANSI 61 approvals), applications have also looked to magnetic flow meters as the preferred choice, especially in applications requiring analog (rate) or pulse (totalized) outputs.
APPLICATIONS AND FEATURES
Cadillac® EMAG Magnetic Flow Meter Applications
The Cadillac® EMAG magnetic flow meter is a totalizing device that is capable of measuring liquids of all types and consistency while providing an obstruction free flow path. This meter can be applied effectively for the following purposes:
- Data Source for energy management system, DCS, district-wide systems.
- Cooling tower Water flow.
- Potable Water flow.
- General industrial and domestic Water flow.
- Industrial and domestic Wastewater flow.
- Aquifer injection Water flow.
- Process Water flow.
- Water based Coolant flow.
- Water based Slurry flow.
- Reclamation Water flow.
- Clarifier Water flow.
Cadillac® EMAG Magnetic Meter Features
The Cadillac® EMAG magnetic flow meter is the number one choice due to accuracy, rangeability, longevity, and modern electronics.
Accuracy
+/-0.5% of the reading for liquids. High accuracy allows significant improvement in both measurement and customer billing.
Rangeability
Typically 100 to 1 turndown or better. With seasonal heating/cooling load variation, the need for a large turndown is essential. Cadillac® magnetic flow meters will accurately measure all load requirements with proper sizing.
Longevity
Mean time between failure (MTBF) of 40 years. With no moving parts and through simple robust design the meter has unmeasured life expectancy.
Modern Electronics
Meeting the challenges of the next millennium. Meters are equipped with electronics capable of registering locally, remotely or interfacing with an energy management system. Built to withstand the toughest conditions.
OPERATION PRINCIPLES
Cadillac® EMAG Magnetic Flow Meter – Principles of Operation
To understand the operation principles for Cadillac® EMAG Magnetic Flow Meter, it’s important to define Faraday’s law. It states that when you move a conductor perpendicular through a magnetic field, a voltage will be induced proportional to the velocity of the conductor. A magnetic field is created by a set of coils which are encapsulated and rigidly retained in the meter flow tube and, when a conductive liquid moves through that magnetic field, a pair of electrodes measures the voltage induced by the movement of the liquid. The measurement is independent of conductivity changes in the liquid as long as it remains above the minimum threshold of 3 uS/cm2.
The relationship between the liquid velocity and the induced voltage is expressed in a meter K-factor. The meter K-factor is unique to each and every meter and is documented during a NIST traceable flow test completed prior to shipment. With the K-factor established a highly accurate volumetric flow is calculated by multiplying the cross sectional area of the flow tube by the measured liquid velocity. This volumetric relationship can then be converted to various engineering units and the flow meter converter can then retransmit this information with a 4-20 mA current signal and/or conditioned pulse. An optional integral LCD Indicator/Totalizer is available to locally display and totalize in whatever engineering units preferred.
DIMENSIONS AND SPECS
Cadillac® EMAG Magnetic Meter – Dimensions
The Cadillac® EMAG magnetic meter’s dimensions are outlined below. Please reference the letters with the chart for each meter size.
Meter Size | 0.5″ | 1.0″ | 1.25″ | 1.5″ | 2.0″ | 2.5″ |
“L1” (face to face) | 7.9″ | 7.9″ | 7.9″ | 7.9″ | 7.9″ | 7.9″ |
“L3” (top to bottom) | 10.0″ | 10.9″ | 11.3″ | 11.6″ | 12.3″ | 13.2″ |
“L2” (centerline to top) | 8.1″ | 8.5″ | 8.7″ | 8.9″ | 9.3″ | 9.8″ |
Weight ANSI Class 150 lb |
20 lbs | 22 lbs | 25 lbs | 28 lbs | 32 lbs | 40 lbs |
Meter Size | 3.0″ | 4.0″ | 5.0″ | 6.0″ | 8.0″ | 10.0″ |
L1 | 7.9″ | 9.8″ | 9.8″ | 11.8″ | 13.8″ | 17.7″ |
L3 | 13.6″ | 14.5″ | 16.1″ | 17.3″ | 19.3″ | 21.4″ |
L2 | 10.0″ | 10.4″ | 11.2″ | 11.8″ | 12.8″ | 13.5″ |
Weight ANSI Class 150 lb |
47 lbs | 61 lbs | 80 lbs | 106 lbs | 145 lbs | 205 lbs |
Meter Size | 12.0″ | 14.0″ | 16.0″ | 18.0″ | 20.0″ | 24.0″ |
L1 | 19.7″ | 21.7″ | 23.6″ | 23.6″ | 23.6″ | 23.6″ |
L3 | 23.2″ | 25.0″ | 27.5″ | 29.6″ | 31.7″ | 26.2″ |
L2 | 14.5″ | 15.4″ | 16.5″ | 17.4″ | 18.3″ | 20.5″ |
Weight ANSI Class 150 lb |
318 lbs | 379 lbs | 465 lbs | 503 lbs | 590 lbs | 897 lbs |
Cadillac® EMAG Magnetic Flow Meter – General Specifications
Cadillac® EMAG Magnetic Flow Meter includes the following specifications:
- Meter will consist of a full-bore body with encapsulated and rigidly retained set of coils.
- Meter available with remote or integral electronics with indication and totalization.
- Meter operates at +/- 0.5% accuracy with proper flow profiling or piping straight run.
- Meter available with pulse and analog (4-20 mA) outputs.
- Modbus-RTU or Profibus-PA communication available as an option
- Meter will provide instantaneous and totalized flow available at local indicator or remotely through outputs.
- Meter measures flow using Faraday’s law (Induce voltage is directly proportional to the velocity of the conductive liquid)
- Meter K-factor is stable and not influenced by external piping or mounting orientation.
- Meter will measure fluids with conductivity greater than or equal to 3.0 uS/cm2.
- Meter will have empty pipe detection and contact (DO) available for alarming.
- Meter power supply: 100-240 VAC, 50/60 Hz (Optional 24Vdc). Maximum power consumption approximately 19Watts.
- Meter will be calibrated to/and be provided with NIST calibration certificate.
INSTALLATION
Cadillac® EMAG Magnetic Flow Meter – Installation
Installation requirements for the Cadillac® EMAG are along the line of conventional magnetic flow meters with industry standard for flow profiling or piping straight run.
Employing an industry standard coil design within the flow tube the Cadillac® meter provides an economical alternative for those applications where the CMAG and its unique coil design and focusing plates are not required or necessary for the application.
The electronics for both the CMAG and EMAG are identical and provide high frequency DC square wave signal generation and flow signal sampling. Providing the high reliability and functionality available for a variety of flow applications.
In practice, installation requirements for the EMAG magnetic flow meter follow standard piping straight run requirements, which are listed as follows:
Downstream of the meter:
- Expander (2-5) diameters
- Tee – (2-5) diameters
- Elbow – (2-5) diameters
- Valves – (2-10) diameters
Upstream of the meter:
- Expander – (10) diameters
- Tee – (5) diameters
- Elbow – (5) diameters
- Valves – (10) diameters
Unlike other technologies such as the Cadillac® Vortex flow meter, magnetic flow meters do not have a low flow cutoff, essentially allowing the meter to read to zero. With such a wide flow range capability for the technology, most applications can be addressed with meters at full line size.
MODEL CODE
EMAG Model Code
Related Articles
Three Tips for Selecting a Hot/Chilled Water BTU System to Improve Accuracy
As far as hot/chilled water BTU measurement systems goes, panel mounted energy computers, volumetric flow meters, and high precision temperature elements have become the technology solution of choice for most facilities and plants. With that being said, in most cases,...
Three Tips for maximizing your Volumetric Flow Meter’s Efficiency
As far as volumetric flow measurement goes, magnetic flow meters have become the flow technology of choice for most facilities and plants looking to incur significant savings on energy, maintenance, and processing costs. Magnetic flow meters are perfect for measuring...
GET A FREE QUOTE FOR YOUR NEEDS